最近閲覧した製品
RCP 401シリーズ
コンサルタント向け資料
製品番号を選択してください:
テキストをコピー
コピーされました!
エラーが発生しました。しばらくしてからもう一度お試しください。
RCP 401 Decorator-Style Remote Control Panel for SMP 400 Series Products
- Provide a Decorator-style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black faceplates.
- Cabling requirements
- Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 401 series product.
- Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 401 (60-1868-01); no alternates or equals
RCP 401 Decorator-Style Remote Control Panel for SMP 400 Series Products
- Provide a Decorator-style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black faceplates.
- Cabling requirements
- Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 401 series product.
- Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 401 (60-1868-01); no alternates or equals
RCP 401 MK mount Remote Control Panel for SMP 400 Series Products
- Provide an MK mounting style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include a white faceplate only.
- Cabling requirements
- Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
- Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 401 MK (60-1868-22); no alternates or equals
RCP 401 MK mount Remote Control Panel for SMP 400 Series Products
- Provide an MK mounting style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include a white faceplate only.
- Cabling requirements
- Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
- Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 401 MK (60-1868-22); no alternates or equals
RCP 401 EU mount Remote Control Panel for SMP 400 Series Products
- Provide an European Union style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black cover plates.
- Device shall be compatible with Extron’s Flex55 mounting systems.
- Cabling requirements
- Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
- Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 401 EU (60-1868-32); no alternates or equals
RCP 401 EU mount Remote Control Panel for SMP 400 Series Products
- Provide an European Union style remote control panel for the purpose of remotely controlling, monitoring and connecting USB storage when paired with an Extron SMP 400 Series Streaming Media Processor.
- Connection Requirements
- USB Requirements
- Provide one rear accessible USB type C port mounted at a right angle to the faceplate.
- Provide one front accessible USB type A receptacle
- Support 12V power connection
- Provide one rear captive screw connection for 12VDC power
- USB Requirements
- Mounting requirements
- Device shall have the ability to be mounted directly in a wall, lectern, or other flat surface and shall be able to be secured using the supplied mud ring and hardware.
- Device shall have the ability to be mounted to the surface of a wall using an optional wall box.
- Device shall include both white and black cover plates.
- Device shall be compatible with Extron’s Flex55 mounting systems.
- Cabling requirements
- Device shall include a 6 foot (1.8 meters) USB-C cable for direct connection to an Extron SMP 400 series product.
- Device may be optionally extended over fiber optic cable up to 492 feet (150 meters) using an Extron UCS 900 Series.
- Shall include backlit rubberized button panel interface.
- Device shall have a total of six soft white LED backlit buttons, dedicated for record, pause, stop, chapter markings, swap and layout preset recall.
- Buttons shall feature two levels of illumination, dim and bright
- Buttons shall illuminate brightly when active, and have the ability to flash
- Record button shall feature red illumination during recording.
- Record button shall have a raised bump to allow user to located it with low visibility
- Shall include status LED indicators
- Device shall have a red and green status LED indicator for alarm and button press activity
- Device shall have a green LED for USB storage indicating:
- Off – no storage is detected, or the location is not configured.
- Green solid – Storage is detected, and the port is configured.
- Green blink – Storage is being written, or accessed.
- Shall include audible warning - buzzer.
- Device shall have an internal buzzer that sounds in conjunction with the status LED.
- Shall include a means to lock out the front panel controls.
- When enabled, the buttons flash 3 times when any one button is pressed.
- Device shall be Section 508 Compliant and shall meet or exceed accessibility standards for Electronic Information Technology
- Shall meet regulatory compliances
- Shall be certified to meet safety compliances under CE, c-UL, and UL
- Shall meet EMI/EMC compliances under CE, C-tick, FCC Class A, ICES, and VCCI
- Shall comply with requirements of RoHS and WEEE
- Shall provide three year parts and labor warranty
- Shall meet regulatory compliances
- Connection Requirements
- Approved device shall be the Extron RCP 401 EU (60-1868-32); no alternates or equals
アイテムをカートに追加する
Order Message Number
製品番号
注: Extron products using the Universal AC Outlet accept a number of different AC plug types. Before use, ensure that the device meets all regulatory requirements for your region and complies with all applicable local safety and electrical codes and standards.
現在の合計金額:

Chrome
Firefox
Edge
Safari