| XTP T HD 4K |
|
specification |
 |
| Frame rate1 | 24, 25, 30, 50, or 60 fps |
| Chroma sampling1 | 4:4:4, 4:2:2, or 4:2:0 |
| Color bit depth1 | 8 bits per color |
| Signal Type | DisplayPort 1.1, DVI 1.0, HDMI 1.4, HDCP 2.3 |
| Max. video data rate | 10.2 Gbps (3.4 Gbps per color) |
| NOTE | 1Subject to the maximum data rate limit. Use our calculator at www.extron.com/8Kdatarate to determine video parameters supported by this data rate. |
|
| | |
| NOTE | The XTP T HD 4K transmitter can be used with XTP receivers, with twisted pair cables linking the transmitter and receiver, or with other Extron XTP products. |
|
|
| Video |
| NOTE | Extron strongly recommends compatibility testing while designing, and before installing, any 3D system. There are several unique 3D formats in use by source devices and display manufacturers. The level of 3D product support is governed by pixel clock, signal format, and communication between source and sink devices. Please contact an Extron Applications Engineer for more information. |
|
| Gain | Unity |
| Resolution range | Up to 2560x1600 @ 60 Hz*, 1080p @ 120 Hz or 4K (4096x2160) @ 30 Hz, UHD (3840x2160) @ 30 Hz, 4K/UHD @ 60 Hz with 4:2:0 chroma subsampling * reduced blanking |
| Signal Type | Single-link HDMI (or DVI-D or DisplayPort) |
| Maximum data rate | 10.2 Gbps (3.4 Gbps per color) |
| Maximum pixel clock | 300 MHz |
| Formats | RGB and YCbCr digital video |
| Standards | DisplayPort 1.1, DVI 1.0, HDMI 1.4; HDCP 2.3 |
|
| Video input and loop-through |
| Number/signal type | 1 single link HDMI (or DVI-D or DisplayPort) input
1 single link HDMI (or DVI-D) loop-through |
| Connectors | 2 female HDMI type A: 1 input, 1 loop-through |
|
| Shielded twisted pair interconnection |
| Connectors | 1 female RJ-45 per unit |
| Termination standards | TIA/EIA T568B |
| Signal transmission distance | 330' (100 m) using shielded twisted pair or XTP DTP 24 cable |
| Cable requirements | Solid conductor, 24 AWG or better |
| Cable recommendations | 400 MHz bandwidth, STP (Shielded Twisted Pair) |
| NOTE | Extron XTP DTP 24 shielded twisted pair cable is strongly recommended for optimal performance. |
|
|
| Audio |
| Gain | Unbalanced output: 0 dB; balanced output: +6 dB |
| Frequency response | 20 Hz to 20 kHz, ±0.5 dB |
| THD + Noise | <0.1%, 20 Hz - 20 kHz at nominal level |
| S/N | >90 dB, at maximum balanced output (unweighted) |
| Crosstalk | ≤-80 dB @ 1 kHz, fully loaded |
| Stereo channel separation | >80 dB @ 1 kHz |
| Sampling Rates | 32 kHz, 44.1 kHz, 48 kHz, 96 kHz, 192 kHz |
| Bit depths | 16, 20, 24 bit |
|
| Audio input |
| Number/signal type | 1 analog stereo, balanced/unbalanced or
1 digital audio, de-embedded from HDMI |
| Connectors | (1) 3.5 mm captive screw connector, 5 pole 1 female HDMI type A (shared with video input) |
| Source formats | LPCM up to 7.1/24-bit/192 kHz, Dolby Atmos®, Dolby® TrueHD, Dolby Digital Plus™, Dolby Digital EX, Dolby Digital 5.1, Dolby Digital 2/0 Surround, Dolby Digital 2/0, DTS-HD Master Audio™, DTS-HD, DTS-ES Discrete 6.1, DTS-ES Matrix 6.1, DTS Digital Surround 5.1, DTS 2 Channel, analog stereo |
| Impedance | 10k ohms, unbalanced, 20k ohms balanced |
| Nominal level | +4 dBu, -10 dBV configurable |
| Maximum level | +21 dBu balanced, +15 dBu unbalanced |
| Input gain adjustment | -18 dB to +24 dB, 1 dB steps, adjustable |
| NOTE | 0 dBu = 0.775 Vrms, 0 dBV = 1 Vrms, 0 dBV ≈ 2 dBu |
|
|
| Communications — transmitter |
| USB control ports | 1 front panel female mini USB B |
| USB standards | USB 2.0, low speed |
| Program control | Extron control/configuration program for Windows® Extron Simple Instruction Set (SIS™) |
|
| Communications — external device (pass-through, unidirectional or bidirectional) |
| Serial control port input/output | 1 set of proprietary signals on a female RJ-45 jack |
| Serial control port output/input | RS-232 (+5 V) via a (1) 3.5 mm, 5 pole captive screw connector (uses 3 poles) (connector is shared with IR control port) |
| Baud rates | Up to 115200 baud |
| Protocol | Data bits = 5 - 8 Stop bits = 1 or 2 Parity = odd, even, none Flow control = XON, XOFF, none |
| Serial control pin configuration | 1 = Tx, 2 = Rx, 3 = GND |
| IR control port | (1) 3.5 mm, captive screw connector, 5 pole (connector is shared with RS-232 control port) TTL level (0 to 5 V) modulated infrared control from 30 kHz up to 56 kHz |
| IR control pin configuration | 3 = GND, 4 = IR Tx, 5 = IR Rx |
| Ethernet pass-through port | 1 female RJ-45 connector |
| Ethernet data rate | 10/100Base-T, half/full duplex with autodetect |
|
| General |
| Power supply | External Input: 100-240 VAC, 50-60 Hz Output: 12 VDC, 1 A, 12 watts |
| Power consumption | |
| Device | 8.0 watts |
| Device and power supply | 9.2 watts |
| NOTE | The XTP transmitter can be powered either locally by an external power supply or remotely using an optional power injector or XTP CrossPoint matrix switcher. |
|
| Ambient temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
| Cooling | Convection, vents on sides and top |
| Thermal dissipation | |
| Device | 26.1 BTU/Hr |
| Device and power supply | 30.2 BTU/Hr |
| Mounting |
| Rack mount | Yes, with optional 1U high rack shelf |
| Furniture mount | Yes, with optional under-desk mounting kit |
| Enclosure type | Metal |
| Enclosure dimensions | 1.0" H x 8.68" W x 6.0" D (half rack wide)
(2.5 cm H x 22.1 cm W x 15.2 cm D)
(Depth excludes connectors.) |
| Product weight | 1.6 lbs (0.7 kg) |
| Regulatory compliance | CE, c-UL, UL, CE**, C-tick, FCC Class A**, ICES, VCCI, WEEE, Complies with the appropriate requirements of RoHS |
| NOTE | **CE and FCC testing is conducted with STP (shielded twisted pair) cable. |
|
| Product warranty | 3 years parts and labor |
| Everlast power supply warranty | 7 years parts and labor |
| NOTE | All nominal levels are at ±10%. |
|
| NOTE | Specifications are subject to change without notice. |
|
| (5741-D8) |