| PS 124 |
|
| General |
| Power output | 12 VDC, regulated; 4 A maximum; 48 watts, total for all 8 outputs |
| NOTE | Maximum output current is rated at an ambient temperature of 40 °C. |
|
| Power input | 100 VAC to 240 VAC, 50-60 Hz |
| No load | 2.0 watts |
| Full power | 55 watts, 0.1 A maximum |
| Ambient temperature/humidity | Storage: -40 to +158 °F (-40 to +70 °C) / 10% to 90%, noncondensing Operating: +32 to +122 °F (0 to +50 °C) / 10% to 90%, noncondensing |
| Cooling | Convection, no vents |
| Thermal dissipation | 22.4 BTU/hr |
| Mounting | |
| Rack mount | Yes, with optional 1U rack shelf |
| Furniture mount | Yes, with optional under-desk mounting kit |
| Pole mount | Yes, with optional mounting kit |
| Enclosure type | Metal |
| Enclosure dimensions | 1.75" H x 4.3" W x 8.5" D (1U high, quarter rack wide) (4.4 cm H x 11.0 cm W x 21.6 cm D) (Depth excludes connectors.) |
| Product weight | 1.2 lbs (0.5 kg) |
| Shipping weight | 3 lbs (2 kg) |
| Vibration | ISTA 1A in carton (International Safe Transit Association) |
| Regulatory compliance | |
| Safety | CE, c-UL, NEC section 300.22 (C), PSE, UL Meets UL 60950-1 and IEC 60950-1. With the installation of the Extron Flexible Conduit kit, meets all applicable requirements of UL 2043 for use in air handling spaces. |
| EMI/EMC | CE, CISPR 22 Class B, C-tick, EN55022 Class B, FCC Class B, ICES Class B, VCCI Class B |
| Environmental | Complies with the appropriate requirements of RoHS, WEEE |
| Product warranty | 3 years parts and labor |
| Everlast power supply warranty | 7 years parts and labor |
| NOTE | All nominal levels are at ±10%. |
|
| NOTE | Specifications are subject to change without notice. |
|
| (8.0-043013-D5) |