IPCP Pro 250 xiは、中小規模AVシステムに対応可能な多機能で高性能なコントロールプロセッサーです。処理性能を強化し、IP Link Proシリーズからメモリを倍増しました。IPCP Pro 250 xiは、複数のセキュアな標準プロトコルに対応するとともに、ギガビットイーサネットインターフェイスを装備、一般的なネットワークインフラを使用して複数のTouchLink® Proタッチパネルやネットワークボタンパネル、IPL EXP拡張インターフェイスを接続可能です。IPCP Pro 250 xiはAVシステムにおいて複数の機器および信号を制御する用途に最適です。
Provide an Ethernet-enabled control processor for the purpose of remotely controlling, monitoring and troubleshooting connected AV equipment and AV systems.
Ethernet-enabled control processor
Provide one RS-232 port on a captive screw connector located on the back of the processor that can be configured for unidirectional or bidirectional control of AV system components.
Provide one RS-232/RS-422/RS-485 port on a captive screw connector located on the back of the processor that can be used for unidirectional or bidirectional control of AV system components.
Provide one IR/Serial port on a captive screw connector located on the back of the processor. This port shall allow the transmission of IR signals (using an IR emitter) or unidirectional RS-232 communications for control of AV system components.
Provide two low voltage relays on captive screw connectors located on the back of the processor that can be used to control lighting, screens, or other device functions.
Provide four digital I/O’s on captive screw connectors that can be used to interface with devices such as sensors, switches, LEDs and relays.
Provide one eBUS® port on a 4-pole captive screw connector located on the back of the control processor for connecting to eBUS devices.
Provide a remote volume control port for the Extron MPA Series and select XTRA™ Series amplifiers.
Supports the creation of IR drivers by capturing IR commands from handheld remotes. IR receiver shall be located on the bottom right front of the processor and integrated into the control processor enclosure.
Device shall have a female RJ-45 jack located on the back of the enclosure that supports 10/100/1000Base-T, half/full duplex with auto-detect for connection to a LAN or WAN and includes link and activity LED indicators located on the left and right of the jack for troubleshooting network issues.
Device shall support the following protocols: ICMP (ping), IEEE 802.1X, IPv4, TCP, UDP, DHCP, DNS, HTTP, HTTPS, NTP, SFTP, SMTP, SNMP, SSH.
Device shall have a 12-volt captive screw connection located on the back of the panel.
Device shall include a multi-function button that allows for the reset of the device or its communication properties at minimum.
Supports a web-based AV resource management application that provides a means to manage, monitor, and control AV equipment.
Provide an internal real-time clock with backup battery that is used to keep track of the date and time.
Device shall have at least 8 GB of nonvolatile memory.
Provide front panel LED activity indicators for power status, eBUS status, RS-232/RS-422/RS-485 status, RS-232 status, IR/S status, digital I/O status, relay status, and network status.
Device shall include an energy-efficient external 12 VDC, 1 A power supply.
Device shall support the addition of an Extron LinkLicense®.
Mounting requirements
Device shall be housed in a 1 RU, quarter rack width metal enclosure.
Device shall be rack mountable using an optional rack shelf.
Device shall be able to be installed under a table, desk, or other flat surface using an optional mounting kit.
Device shall be mountable on a projector mounting pole using an optional mounting kit.
Software requirements
The device may only be configured or programmed using Extron’s Global Configurator Plus or Professional, or Global Scripter respectively.
Device drivers and modules can be obtained through Extron support resources and database.
Shall be configured or programmed by an Extron authorized user.
The device's configuration and settings shall be managed using Extron's Toolbelt software.
Security Requirements
Device shall support SFTP and SSH for secure communication between the control processor and a TouchLink Pro touchpanel or Network Button Panel.
Device shall support HTTPS and SSH for secure communication between the control processor and Extron Control App.
Device shall support HTTPS for secure communication between the control processor and Extron Control for Web.
Device shall support SSH for secure communication between the control processor and controlled device for programmed systems.
Device shall support SFTP and SSH for secure communication between the control processor and the configuration or programming software.
Device shall provide the option to modify administrator and user credentials.
Device shall support security updates to maintain network health.
Device shall require that a Secure Socket Layer (SSL) Certificate is installed to maintain system confidentiality and data integrity.
Device shall support the installation of an owner furnished certificate with the following properties:
Certificates shall include x.509 support
Certificates shall include public / private key exchange
Certificates shall support PEM encoding
Extron shall furnish documentation that describes all supported network ports and services.
Shall meet regulatory compliances:
CE
c-UL
UL
C-Tick
FCC Class A
ICES
VCCI
RoHs
WEEE
Product Warranty
Shall provide at least 3 years parts and labor.
Approved device shall be the Extron IPCP Pro 250 xi, part number 60-1911-01; no alternates or equals
IPCP Pro 250 xi
Provide an Ethernet-enabled control processor for the purpose of remotely controlling, monitoring and troubleshooting connected AV equipment and AV systems.
Ethernet-enabled control processor
Provide one RS-232 port on a captive screw connector located on the back of the processor that can be configured for unidirectional or bidirectional control of AV system components.
Provide one RS-232/RS-422/RS-485 port on a captive screw connector located on the back of the processor that can be used for unidirectional or bidirectional control of AV system components.
Provide one IR/Serial port on a captive screw connector located on the back of the processor. This port shall allow the transmission of IR signals (using an IR emitter) or unidirectional RS-232 communications for control of AV system components.
Provide two low voltage relays on captive screw connectors located on the back of the processor that can be used to control lighting, screens, or other device functions.
Provide four digital I/O’s on captive screw connectors that can be used to interface with devices such as sensors, switches, LEDs and relays.
Provide one eBUS® port on a 4-pole captive screw connector located on the back of the control processor for connecting to eBUS devices.
Provide a remote volume control port for the Extron MPA Series and select XTRA™ Series amplifiers.
Supports the creation of IR drivers by capturing IR commands from handheld remotes. IR receiver shall be located on the bottom right front of the processor and integrated into the control processor enclosure.
Device shall have a female RJ-45 jack located on the back of the enclosure that supports 10/100/1000Base-T, half/full duplex with auto-detect for connection to a LAN or WAN and includes link and activity LED indicators located on the left and right of the jack for troubleshooting network issues.
Device shall support the following protocols: ICMP (ping), IEEE 802.1X, IPv4, TCP, UDP, DHCP, DNS, HTTP, HTTPS, NTP, SFTP, SMTP, SNMP, SSH.
Device shall have a 12-volt captive screw connection located on the back of the panel.
Device shall include a multi-function button that allows for the reset of the device or its communication properties at minimum.
Supports a web-based AV resource management application that provides a means to manage, monitor, and control AV equipment.
Provide an internal real-time clock with backup battery that is used to keep track of the date and time.
Device shall have at least 8 GB of nonvolatile memory.
Provide front panel LED activity indicators for power status, eBUS status, RS-232/RS-422/RS-485 status, RS-232 status, IR/S status, digital I/O status, relay status, and network status.
Device shall include an energy-efficient external 12 VDC, 1 A power supply.
Device shall support the addition of an Extron LinkLicense®.
Mounting requirements
Device shall be housed in a 1 RU, quarter rack width metal enclosure.
Device shall be rack mountable using an optional rack shelf.
Device shall be able to be installed under a table, desk, or other flat surface using an optional mounting kit.
Device shall be mountable on a projector mounting pole using an optional mounting kit.
Software requirements
The device may only be configured or programmed using Extron’s Global Configurator Plus or Professional, or Global Scripter respectively.
Device drivers and modules can be obtained through Extron support resources and database.
Shall be configured or programmed by an Extron authorized user.
The device's configuration and settings shall be managed using Extron's Toolbelt software.
Security Requirements
Device shall support SFTP and SSH for secure communication between the control processor and a TouchLink Pro touchpanel or Network Button Panel.
Device shall support HTTPS and SSH for secure communication between the control processor and Extron Control App.
Device shall support HTTPS for secure communication between the control processor and Extron Control for Web.
Device shall support SSH for secure communication between the control processor and controlled device for programmed systems.
Device shall support SFTP and SSH for secure communication between the control processor and the configuration or programming software.
Device shall provide the option to modify administrator and user credentials.
Device shall support security updates to maintain network health.
Device shall require that a Secure Socket Layer (SSL) Certificate is installed to maintain system confidentiality and data integrity.
Device shall support the installation of an owner furnished certificate with the following properties:
Certificates shall include x.509 support
Certificates shall include public / private key exchange
Certificates shall support PEM encoding
Extron shall furnish documentation that describes all supported network ports and services.
Shall meet regulatory compliances:
CE
c-UL
UL
C-Tick
FCC Class A
ICES
VCCI
RoHs
WEEE
Product Warranty
Shall provide at least 3 years parts and labor.
Approved device shall be the Extron IPCP Pro 250 xi, part number 60-1911-01; no alternates or equals
IPCP Pro 250 xi
Provide an Ethernet-enabled control processor for the purpose of remotely controlling, monitoring and troubleshooting connected AV equipment and AV systems.
Ethernet-enabled control processor
Provide one RS-232 port on a captive screw connector located on the back of the processor that can be configured for unidirectional or bidirectional control of AV system components.
Provide one RS-232/RS-422/RS-485 port on a captive screw connector located on the back of the processor that can be used for unidirectional or bidirectional control of AV system components.
Provide one IR/Serial port on a captive screw connector located on the back of the processor. This port shall allow the transmission of IR signals (using an IR emitter) or unidirectional RS-232 communications for control of AV system components.
Provide two low voltage relays on captive screw connectors located on the back of the processor that can be used to control lighting, screens, or other device functions.
Provide four digital I/O’s on captive screw connectors that can be used to interface with devices such as sensors, switches, LEDs and relays.
Provide one eBUS® port on a 4-pole captive screw connector located on the back of the control processor for connecting to eBUS devices.
Provide a remote volume control port for the Extron MPA Series and select XTRA™ Series amplifiers.
Supports the creation of IR drivers by capturing IR commands from handheld remotes. IR receiver shall be located on the bottom right front of the processor and integrated into the control processor enclosure.
Device shall have a female RJ-45 jack located on the back of the enclosure that supports 10/100/1000Base-T, half/full duplex with auto-detect for connection to a LAN or WAN and includes link and activity LED indicators located on the left and right of the jack for troubleshooting network issues.
Device shall support the following protocols: ICMP (ping), IEEE 802.1X, IPv4, TCP, UDP, DHCP, DNS, HTTP, HTTPS, NTP, SFTP, SMTP, SNMP, SSH.
Device shall have a 12-volt captive screw connection located on the back of the panel.
Device shall include a multi-function button that allows for the reset of the device or its communication properties at minimum.
Supports a web-based AV resource management application that provides a means to manage, monitor, and control AV equipment.
Provide an internal real-time clock with backup battery that is used to keep track of the date and time.
Device shall have at least 8 GB of nonvolatile memory.
Provide front panel LED activity indicators for power status, eBUS status, RS-232/RS-422/RS-485 status, RS-232 status, IR/S status, digital I/O status, relay status, and network status.
Device shall include an energy-efficient external 12 VDC, 1 A power supply.
Device shall include an Extron LinkLicense® for User Interfaces.
Mounting requirements
Device shall be housed in a 1 RU, quarter rack width metal enclosure.
Device shall be rack mountable using an optional rack shelf.
Device shall be able to be installed under a table, desk, or other flat surface using an optional mounting kit.
Device shall be mountable on a projector mounting pole using an optional mounting kit.
Software requirements
The device may only be configured or programmed using Extron’s Global Configurator Plus or Professional, or Global Scripter respectively.
Device drivers and modules can be obtained through Extron support resources and database.
Shall be configured or programmed by an Extron authorized user.
The device's configuration and settings shall be managed using Extron's Toolbelt software.
Security Requirements
Device shall support SFTP and SSH for secure communication between the control processor and a TouchLink Pro touchpanel or Network Button Panel.
Device shall support HTTPS and SSH for secure communication between the control processor and Extron Control App.
Device shall support HTTPS for secure communication between the control processor and Extron Control for Web.
Device shall support SSH for secure communication between the control processor and controlled device for programmed systems.
Device shall support SFTP and SSH for secure communication between the control processor and the configuration or programming software.
Device shall provide the option to modify administrator and user credentials.
Device shall support security updates to maintain network health.
Device shall require that a Secure Socket Layer (SSL) Certificate is installed to maintain system confidentiality and data integrity.
Device shall support the installation of an owner furnished certificate with the following properties:
Certificates shall include x.509 support
Certificates shall include public / private key exchange
Certificates shall support PEM encoding
Extron shall furnish documentation that describes all supported network ports and services.
Shall meet regulatory compliances:
CE
c-UL
UL
C-Tick
FCC Class A
ICES
VCCI
RoHs
WEEE
Product Warranty
Shall provide at least 3 years parts and labor.
Approved device shall be the Extron IPCP Pro 250 xi, part number 60-1911-01A; no alternates or equals.
IPCP Pro 250 xi
Provide an Ethernet-enabled control processor for the purpose of remotely controlling, monitoring and troubleshooting connected AV equipment and AV systems.
Ethernet-enabled control processor
Provide one RS-232 port on a captive screw connector located on the back of the processor that can be configured for unidirectional or bidirectional control of AV system components.
Provide one RS-232/RS-422/RS-485 port on a captive screw connector located on the back of the processor that can be used for unidirectional or bidirectional control of AV system components.
Provide one IR/Serial port on a captive screw connector located on the back of the processor. This port shall allow the transmission of IR signals (using an IR emitter) or unidirectional RS-232 communications for control of AV system components.
Provide two low voltage relays on captive screw connectors located on the back of the processor that can be used to control lighting, screens, or other device functions.
Provide four digital I/O’s on captive screw connectors that can be used to interface with devices such as sensors, switches, LEDs and relays.
Provide one eBUS® port on a 4-pole captive screw connector located on the back of the control processor for connecting to eBUS devices.
Provide a remote volume control port for the Extron MPA Series and select XTRA™ Series amplifiers.
Supports the creation of IR drivers by capturing IR commands from handheld remotes. IR receiver shall be located on the bottom right front of the processor and integrated into the control processor enclosure.
Device shall have a female RJ-45 jack located on the back of the enclosure that supports 10/100/1000Base-T, half/full duplex with auto-detect for connection to a LAN or WAN and includes link and activity LED indicators located on the left and right of the jack for troubleshooting network issues.
Device shall support the following protocols: ICMP (ping), IEEE 802.1X, IPv4, TCP, UDP, DHCP, DNS, HTTP, HTTPS, NTP, SFTP, SMTP, SNMP, SSH.
Device shall have a 12-volt captive screw connection located on the back of the panel.
Device shall include a multi-function button that allows for the reset of the device or its communication properties at minimum.
Supports a web-based AV resource management application that provides a means to manage, monitor, and control AV equipment.
Provide an internal real-time clock with backup battery that is used to keep track of the date and time.
Device shall have at least 8 GB of nonvolatile memory.
Provide front panel LED activity indicators for power status, eBUS status, RS-232/RS-422/RS-485 status, RS-232 status, IR/S status, digital I/O status, relay status, and network status.
Device shall include an energy-efficient external 12 VDC, 1 A power supply.
Device shall include an Extron LinkLicense® for User Interfaces.
Mounting requirements
Device shall be housed in a 1 RU, quarter rack width metal enclosure.
Device shall be rack mountable using an optional rack shelf.
Device shall be able to be installed under a table, desk, or other flat surface using an optional mounting kit.
Device shall be mountable on a projector mounting pole using an optional mounting kit.
Software requirements
The device may only be configured or programmed using Extron’s Global Configurator Plus or Professional, or Global Scripter respectively.
Device drivers and modules can be obtained through Extron support resources and database.
Shall be configured or programmed by an Extron authorized user.
The device's configuration and settings shall be managed using Extron's Toolbelt software.
Security Requirements
Device shall support SFTP and SSH for secure communication between the control processor and a TouchLink Pro touchpanel or Network Button Panel.
Device shall support HTTPS and SSH for secure communication between the control processor and Extron Control App.
Device shall support HTTPS for secure communication between the control processor and Extron Control for Web.
Device shall support SSH for secure communication between the control processor and controlled device for programmed systems.
Device shall support SFTP and SSH for secure communication between the control processor and the configuration or programming software.
Device shall provide the option to modify administrator and user credentials.
Device shall support security updates to maintain network health.
Device shall require that a Secure Socket Layer (SSL) Certificate is installed to maintain system confidentiality and data integrity.
Device shall support the installation of an owner furnished certificate with the following properties:
Certificates shall include x.509 support
Certificates shall include public / private key exchange
Certificates shall support PEM encoding
Extron shall furnish documentation that describes all supported network ports and services.
Shall meet regulatory compliances:
CE
c-UL
UL
C-Tick
FCC Class A
ICES
VCCI
RoHs
WEEE
Product Warranty
Shall provide at least 3 years parts and labor.
Approved device shall be the Extron IPCP Pro 250 xi, part number 60-1911-01A; no alternates or equals.
アイテムをカートに追加する
Order Message Number
製品番号
注: Extron products using the Universal AC Outlet accept a number of different AC plug types. Before use, ensure that the device meets all regulatory requirements for your region and complies with all applicable local safety and electrical codes and standards.
現在の合計金額:
IPCP Pro 250 xi -
Annotation Graphics Processor
To view this page ensure that Adobe Flash Player version
11.0.0 or greater is installed and enabled.